prev
Numbers Carried
Company Number Date From
GCR 1052 m/e 11/1902
LNER (1924) 6052   01/11/1924
LNER (1946) 3200   07/09/1946
BR 63200 w/e 09/10/1948

Locomotive Specifics
Designer J. Robinson
Class Q4
Company History GCR/LNER
Rebuild History
ClassFrom
Q4/111/1902
Q4/201/11/1924
Q4/128/12/1946
Wheels 0-8-0
Builder Neilson, Reid & Co.
Works Number 6251
To Service During 11/1902
Withdrawal Mon 05/09/1949 off Ardsley (ARD)
Service Life 46 yrs, 10 mths , 5 dys

Notes
Notes Cut up at Gorton

Allocations
Code Name From Date
GOR Gorton 24/07/1919
MEX Mexborough 16/02/1924
CLK Colwick 01/01/1931
LNG Langwith Junction 09/01/1931
RET Retford Thrumpton (G.C.) 03/08/1943
ARD Ardsley 05/10/1947
   Withdrawn 05/09/1949

SLS Allocations*
Type Code Name From Date
ALLOC ARD Ardsley 05/10/1947

* Stephenson Locomotive Society data - raw and not yet cross-referenced
Modifications
Date Modified Modification
11/1902 Diagram 17Sat boiler fitted (number 335)
07/01/1907 Diagram 17Sat boiler fitted (number 336)
04/01/1908 Diagram 17Sup boiler fitted (number 848)
25/11/1911 Diagram 17Sat boiler fitted (number 1267)
30/06/1917 Diagram 17Sat boiler fitted (number 478)
05/08/1922 Diagram 17Sat boiler fitted (number 854)
01/11/1924 Diagram 19A boiler fitted (number 592)
12/1928 Modified to conform to LNER Gauge
10/08/1929 Diagram 17Sup boiler fitted (number 468)
14/05/1932 Diagram 17Sup boiler fitted (number 891)
17/11/1934 Diagram 17Sup boiler fitted (number 1634)
06/02/1937 Diagram 17Sat boiler fitted (number 839)
08/07/1939 Diagram 17Sup boiler fitted (number 830)
29/04/1944 Diagram 17Sup boiler fitted (number 185)
28/12/1946 Diagram 17Sat boiler fitted (number 3767)
09/10/1948 Diagram 17Sup boiler fitted (number 913)


Works Visits
Works Entry Departure Durn Level of Work Mileage
Gorton Works 1907 01/1907   General  
Gorton Works 1908 04/01/1908   General
Boiler number 848 (Diagram 17Sup)
 
Gorton Works 1911 25/11/1911   General
Boiler number 1267 (Diagram 17Sat)
 
Gorton Works 1917 30/06/1917   General
Boiler number 478 (Diagram 17Sat)
 
Gorton Works 15/04/1922 05/08/1922 113 days General
Boiler number 854 (Diagram 17Sat)
 
Gorton Works 12/07/1924 01/11/1924 113 days General
Boiler number 592 (Diagram 19A)
Renumbered to LNER (1924) number 6052
 
Gorton Works 26/02/1927 16/04/1927 50 days General  
Gorton Works 29/06/1929 10/08/1929 43 days General
Boiler number 468 (Diagram 17Sup)
 
Gorton Works 30/04/1932 14/05/1932 15 days General
Boiler number 891 (Diagram 17Sup)
 
Gorton Works 03/11/1934 17/11/1934 15 days General
Boiler number 1634 (Diagram 17Sup)
 
Gorton Works 23/01/1937 06/02/1937 15 days General
Boiler number 839 (Diagram 17Sat)
 
Gorton Works 17/06/1939 08/07/1939 22 days General
Boiler number 830 (Diagram 17Sup)
 
Gorton Works 15/11/1941 20/12/1941 36 days General  
Gorton Works 22/04/1944 29/04/1944 8 days Heavy
Boiler number 185 (Diagram 17Sup)
 
Gorton Works 07/12/1946 28/12/1946 22 days General
New cylinders
Boiler number 3767 (Diagram 17Sat)
 
Gorton Works 02/10/1948 09/10/1948 8 days Heavy
New cylinders
Boiler number 913 (Diagram 17Sup)
Renumbered to BR 63200
 

Summary
Date Event Details Source See Also
11/1902 To Service To service as GCR Number 1052
Built at Neilson, Reid & Co., Works Number 6251
Diagram 17Sat boiler fitted
   
1907 Works Visit Works Visit - Gorton Works (General) - Arr: ?/1907. Dep: ?/01/1907.    
07/01/1907 Modification Diagram 17Sat number 336 boiler fitted    
1908 Works Visit Works Visit - Gorton Works (General) - Arr: ?/1908. Dep: 04/01/1908.
Work undertaken:
Boiler number 848 (Diagram 17Sup)
   
1911 Works Visit Works Visit - Gorton Works (General) - Arr: ?/1911. Dep: 25/11/1911.
Work undertaken:
Boiler number 1267 (Diagram 17Sat)
   
1917 Works Visit Works Visit - Gorton Works (General) - Arr: ?/1917. Dep: 30/06/1917.
Work undertaken:
Boiler number 478 (Diagram 17Sat)
   
24/07/1919 Allocation Reallocated to Gorton (GOR)    
15/04/1922 Works Visit Works Visit - Gorton Works (General) - Arr: 15/04/1922. Dep: 05/08/1922.
Work undertaken:
Boiler number 854 (Diagram 17Sat)
   
16/02/1924 Allocation Reallocated to Mexborough (MEX)    
12/07/1924 Works Visit Works Visit - Gorton Works (General) - Arr: 12/07/1924. Dep: 01/11/1924.
Work undertaken:
Boiler number 592 (Diagram 19A)
Renumbered to LNER (1924) number 6052
   
26/02/1927 Works Visit Works Visit - Gorton Works (General) - Arr: 26/02/1927. Dep: 16/04/1927.    
12/1928 Modification Modification: Modified to conform to LNER Gauge    
29/06/1929 Works Visit Works Visit - Gorton Works (General) - Arr: 29/06/1929. Dep: 10/08/1929.
Work undertaken:
Boiler number 468 (Diagram 17Sup)
   
01/01/1931 Allocation Reallocated to Colwick (CLK)    
09/01/1931 Allocation Reallocated to Langwith Junction (LNG)    
30/04/1932 Works Visit Works Visit - Gorton Works (General) - Arr: 30/04/1932. Dep: 14/05/1932.
Work undertaken:
Boiler number 891 (Diagram 17Sup)
   
03/11/1934 Works Visit Works Visit - Gorton Works (General) - Arr: 03/11/1934. Dep: 17/11/1934.
Work undertaken:
Boiler number 1634 (Diagram 17Sup)
   
23/01/1937 Works Visit Works Visit - Gorton Works (General) - Arr: 23/01/1937. Dep: 06/02/1937.
Work undertaken:
Boiler number 839 (Diagram 17Sat)
   
17/06/1939 Works Visit Works Visit - Gorton Works (General) - Arr: 17/06/1939. Dep: 08/07/1939.
Work undertaken:
Boiler number 830 (Diagram 17Sup)
   
15/11/1941 Works Visit Works Visit - Gorton Works (General) - Arr: 15/11/1941. Dep: 20/12/1941.    
03/08/1943 Allocation Reallocated to Retford Thrumpton (G.C.) (RET)    
22/04/1944 Works Visit Works Visit - Gorton Works (Heavy) - Arr: 22/04/1944. Dep: 29/04/1944.
Work undertaken:
Boiler number 185 (Diagram 17Sup)
   
07/09/1946 Renumbered Renumbered to 3200    
07/12/1946 Works Visit Works Visit - Gorton Works (General) - Arr: 07/12/1946. Dep: 28/12/1946.
Work undertaken:
New cylinders
Boiler number 3767 (Diagram 17Sat)
   
05/10/1947 Allocation Reallocated to Ardsley (ARD)    
02/10/1948 Works Visit Works Visit - Gorton Works (Heavy) - Arr: 02/10/1948. Dep: 09/10/1948.
Work undertaken:
New cylinders
Boiler number 913 (Diagram 17Sup)
Renumbered to BR 63200
   
05/09/1949 Withdrawn Condemned as 63200 from Ardsley (ARD)    

prev